{"id":14323,"date":"2025-06-16T17:46:50","date_gmt":"2025-06-16T15:46:50","guid":{"rendered":"https:\/\/www.autosteer.cc\/?p=14323"},"modified":"2025-09-22T09:05:08","modified_gmt":"2025-09-22T07:05:08","slug":"teensy-panda-pc-version-2-gruen","status":"publish","type":"post","link":"https:\/\/www.autosteer.cc\/en\/teensy-panda-pc-version-2-gruen\/","title":{"rendered":"Teensy \u2013 Panda PC \u2013 Version 2 (green)"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"926\" height=\"1024\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-926x1024.png\" alt=\"\" class=\"wp-image-14325\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-926x1024.png 926w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-271x300.png 271w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-768x849.png 768w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-1389x1536.png 1389w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-600x663.png 600w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image.png 1447w\" sizes=\"auto, (max-width: 926px) 100vw, 926px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PCB Details:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Arduino Teensy with Ethernet<\/li>\n\n\n\n<li>ADS1115 (soldered)<\/li>\n\n\n\n<li>Ardusimple simpleRTK2B slot<\/li>\n\n\n\n<li>Septentrio slot<\/li>\n\n\n\n<li>Bynav slot<\/li>\n\n\n\n<li>Integrated Motor Controller<\/li>\n\n\n\n<li>Reverse polarity protection<\/li>\n\n\n\n<li>Input protection with optocouplers<\/li>\n\n\n\n<li>I2C \u2013 via Wago and QWICC Connector<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Circuit board supply voltage<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fuse the 12-15V supply directly after the connector on the tractor with a 10A fuse.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Entrances<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>On\/Off switch<\/li>\n\n\n\n<li>4 digital inputs (3+1 interrupt) Normally open GND to GND Switches for steering, work, remote<\/li>\n\n\n\n<li>3 12V inputs for steering, work, remote<\/li>\n\n\n\n<li>Steering angle sensor<\/li>\n\n\n\n<li>1 x Analog 0-5 V<\/li>\n\n\n\n<li>1 x Analog 0-12V<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exits<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>5 V \u2013 max 800 mA<\/li>\n\n\n\n<li>12 V (input voltage) max 2 A<\/li>\n\n\n\n<li>Output for motor controller = input voltage<\/li>\n\n\n\n<li>2 x CAN bus<\/li>\n\n\n\n<li>Ethernet for operation<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Electrical data<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power supply 12 V to 15 V DC<\/li>\n\n\n\n<li>Current consumption 200 mA at 13.0 V (without motor)&nbsp;<\/li>\n\n\n\n<li>Output for 5V DC and 12V DC<\/li>\n\n\n\n<li>Dimensions<\/li>\n\n\n\n<li>160 mm x 120 mm x 35 mm (lxwxh)<\/li>\n\n\n\n<li>work environment<\/li>\n\n\n\n<li>Operating temperature \u221240 \u00b0C to +85 \u00b0C<\/li>\n\n\n\n<li>Storage temperature \u221240 \u00b0C to +85 \u00b0C<\/li>\n\n\n\n<li>RoHS compliant<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Connections<\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>USB port<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"258\" height=\"364\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-1.png\" alt=\"\" class=\"wp-image-14328\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-1.png 258w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-1-213x300.png 213w\" sizes=\"auto, (max-width: 258px) 100vw, 258px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The USB port on the Teensy is only needed for programming.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Power supply for the circuit board <\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"801\" height=\"511\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-2.png\" alt=\"\" class=\"wp-image-11857\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-2.png 801w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-2-300x191.png 300w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-2-768x490.png 768w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-2-600x383.png 600w\" sizes=\"auto, (max-width: 801px) 100vw, 801px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use 12V from the tractor \u2013 fuse with 10A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fuse is always placed directly at the plug and is intended to protect the cable. <br>If you are taking power directly from the battery, the fuse should be placed there; if you are using the 3-pin tractor socket, then place it directly at the plug.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Labels INPUT BAT + and BAT-<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12V from the tractor (voltage at the tractor is between 12-14 volts)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The bridge from output to input M <\/strong>supplies power to the engine controller after the relay has engaged.<br><br>Between the output and input of a motor controller, one can connect a <strong>12V to 24V StepUp <\/strong>Provides the option to run the motor at 24V if necessary (it will spin faster).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Motor A and B<\/strong> This is the connection for the steering motor \u2013 a 0-12V proportional valve can also be connected here (+ per side to motor A and B). Take the ground from the tractor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>On\/Off switch<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"268\" height=\"325\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-2.png\" alt=\"\" class=\"wp-image-14329\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-2.png 268w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-2-247x300.png 247w\" sizes=\"auto, (max-width: 268px) 100vw, 268px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The bridge at On\/off switches the board on \u2013 the black relay then engages and the motor controller or the 12V output has power.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An external switch can be installed here.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is also a connection for an LED.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">Inputs \u2013 Analog<\/h1>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"511\" height=\"1024\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-511x1024.jpg\" alt=\"\" class=\"wp-image-11859\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-511x1024.jpg 511w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-150x300.jpg 150w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-768x1538.jpg 768w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-767x1536.jpg 767w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1-600x1202.jpg 600w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/img-7498-1.jpg 799w\" sizes=\"auto, (max-width: 511px) 100vw, 511px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Steer on\/off S on GND<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Switch to activate the steering (de-energized \u2013 ground to ground)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This contact enables steering. It can be controlled, for example, via a microswitch on the motor, which switches off the motor when folded away.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The switch must be set to \"Switch\" in the module configuration in AgOpen! <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A green dot == steering active \u2013 means a closed switch.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"276\" height=\"234\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-4.png\" alt=\"\" class=\"wp-image-11860\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Tractor symbol<br>Green: Steering activated<br>Red: Steering off<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Orange: not a trace<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Work on\/off s on gnd<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Switch to activate recording (de-energized \u2013 ground to ground)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This must be configured accordingly in the AgOpen configuration.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"777\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5-1024x777.png\" alt=\"\" class=\"wp-image-11861\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5-1024x777.png 1024w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5-300x228.png 300w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5-768x583.png 768w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5-600x456.png 600w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-5.png 1516w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Bridge S+W<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"314\" height=\"370\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-6.png\" alt=\"\" class=\"wp-image-11862\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-6.png 314w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-6-255x300.png 255w\" sizes=\"auto, (max-width: 314px) 100vw, 314px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Activate recording while steering<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">12V inputs for Work\/Steer<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"580\" height=\"611\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-7.png\" alt=\"\" class=\"wp-image-11863\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-7.png 580w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-7-285x300.png 285w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">These connections are used to activate Steer\/ Work \/ Remote with a 12V signal.<br><strong>Caution: Always use 12V and GND from the external switch!<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Steering angle sensor<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"591\" height=\"276\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-3.png\" alt=\"\" class=\"wp-image-14330\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-3.png 591w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-3-300x140.png 300w\" sizes=\"auto, (max-width: 591px) 100vw, 591px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">5V and GND as power supply for the sensor<br>The signal from the sensor to signal.<br><br>If using an existing steering angle sensor, please test the signal with a multimeter beforehand. <br><br><strong>MAXIMUM 5 V<\/strong> \u2013 Typically, the sensors have a range of 0.5 \u2013 4.5 V. Please always test beforehand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most sensors also have a specific reading range. This is usually located directly at the connector or exactly the opposite \u2013 test this beforehand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pre-wired sensors require GND and a signal from the sensor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Signal to signal and GND is connected to A1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The software uses differential read. (a2d Converter)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"501\" height=\"656\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-9.png\" alt=\"\" class=\"wp-image-11865\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-9.png 501w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-9-229x300.png 229w\" sizes=\"auto, (max-width: 501px) 100vw, 501px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Compass and tilt sensor connection<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The internal module is connected to the main board or the relay board via the QWICC connector.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">12V and 5V analog inputs<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"292\" height=\"280\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-4.png\" alt=\"\" class=\"wp-image-14331\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Pressure Sensor 0-5 V<\/td><td>24<\/td><\/tr><tr><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><\/tr><tr><td>12V input<\/td><td>27<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">The inputs go to the following Teensy pins with voltage components. <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The code needs to be customized.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ampere Sensor<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is directly connected to the motor controller and can be activated in AgOpen.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"878\" height=\"601\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-5.png\" alt=\"\" class=\"wp-image-14332\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-5.png 878w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-5-300x205.png 300w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-5-768x526.png 768w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-5-600x411.png 600w\" sizes=\"auto, (max-width: 878px) 100vw, 878px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">CAN bus<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"426\" height=\"211\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-11.png\" alt=\"\" class=\"wp-image-11867\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-11.png 426w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2023\/06\/image-11-300x149.png 300w\" sizes=\"auto, (max-width: 426px) 100vw, 426px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The connectors are labeled incorrectly. CAN1 = CAN2 in the software. <br>A 120 Ohm resistor is installed on the circuit board. It is activated when the jumpers are set. A jumper is recommended and included for use with Allnav motors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><br>Compass and tilt sensor<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"562\" height=\"546\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-6.png\" alt=\"\" class=\"wp-image-14333\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-6.png 562w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-6-300x291.png 300w\" sizes=\"auto, (max-width: 562px) 100vw, 562px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><br>UART \u2013 RVC Mode<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>We support<\/strong> and is the standard for Bno085<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the compass is ordered including mounting, I will install it permanently on the circuit board.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>GNSS Receiver<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"1014\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-7.png\" alt=\"\" class=\"wp-image-14334\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-7.png 760w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-7-225x300.png 225w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-7-600x801.png 600w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">UNO-format slot for Septentrio or F9P Single <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I supply an adapter board for the Bynav receiver.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ethernet connection<\/strong><\/p>\n\n\n\n<div class=\"wp-block-cover\"><img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"482\" class=\"wp-block-cover__image-background wp-image-14335\" alt=\"\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-8.png\" data-object-fit=\"cover\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-8.png 461w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-8-287x300.png 287w\" sizes=\"auto, (max-width: 461px) 100vw, 461px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Connect the network cable here.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XBEE slot<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"372\" height=\"373\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-9.png\" alt=\"\" class=\"wp-image-14337\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-9.png 372w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-9-150x150.png 150w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-9-300x300.png 300w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-9-100x100.png 100w\" sizes=\"auto, (max-width: 372px) 100vw, 372px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">It's possible to install a Bluetooth or WLAN module in a beer to receive RTK corrections. <br>Or to forward the RTK position from the receiver.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Motor Enable\/Brake Jumper<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"537\" height=\"533\" src=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-10.png\" alt=\"\" class=\"wp-image-14339\" srcset=\"https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-10.png 537w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-10-150x150.png 150w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-10-300x298.png 300w, https:\/\/www.autosteer.cc\/wp-content\/uploads\/2025\/06\/image-10-100x100.png 100w\" sizes=\"auto, (max-width: 537px) 100vw, 537px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">When used with a DC motor, a jumper must be placed on one of the two slots.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Enable (standard delivery) <\/strong>\u2013 Here, the two buttons are inactive and the motor controller must first be activated by Agopen. The advantage is that the motor controller then has no braking effect (resistance) when idling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Brake<\/strong> \u2013 Controller always active \u2013 brakes when stationary \u2013 buttons usable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>PCB Details: Board supply voltage Inputs Outputs Electrical data Connections USB port The USB port on the Teensy is only used for\u2026<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[275],"tags":[],"class_list":["post-14323","post","type-post","status-publish","format-standard","hentry","category-neue-teensy-pcb"],"_links":{"self":[{"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/posts\/14323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/comments?post=14323"}],"version-history":[{"count":6,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/posts\/14323\/revisions"}],"predecessor-version":[{"id":14550,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/posts\/14323\/revisions\/14550"}],"wp:attachment":[{"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/media?parent=14323"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/categories?post=14323"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.autosteer.cc\/en\/wp-json\/wp\/v2\/tags?post=14323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}