Connect the RS232 cable to COM 3 on the receiver.

Open ByConnect

CON (press gear icon)

Connection Settings – Add Row
Select the COM port on the computer
115200 baud

Press Open – close window

Expand (Top right – the image says to press Collapse to open the config file)

Explanation of commands for AgOpenGps T1-FD – Uses COM3

unlogallTurns off all messagesturn off all messages
rtktype roverThe receiver is a roverreceiver is a rover
WORKFREQS ALL ALLUses all frequenciesuse all frequencies
SET OBSFREQ 10Set to 10 Hertzrun at 10 hertz
Heading offset 90GPS and heading antenna on the left and right sides of the tractorGPS and heading antenna left and right on tractor
DUALANTENNAPOWER Onactivates the heading antennaturn on second antenna for heading a roll
RTKTIMEOUT 500Receiver operates for 500 seconds without RTCM corrections using RTK FIXkeep rtk for 500 sec without rtcm corrections
INTERFACEMODE COM3 AUTO AUTOInterface settingsuse automatic input output for com3 interface
SNRCUTOFF 15Satellites below 15 degrees in orbit are not used.don't use satellites below 15 degrees on the orbit
LOG KSXT ONTIME 0.1KSXT Afteruse ksxt message for position, heading and roll for agopengps
saveconfigSave allsave configuration
rebootRestart (required after changes)reboot receiver to work with above config (important)

C1-FD on the PCB from www.autosteer.cc
when using bynav C1-FD module on www.autosteer.cc PCB use COM1 for output:

INTERFACEMODE COM1 AUTO AUTO
log com1 KSXT ONTIME 0.1
saveconfig
reboot

T1-FD as a separate receiver / Special Commands when using T1-FD as a separate receiver

Use T1-FD Ethernet to send data to AgOpenGpsT1-FD using ethernet on bynav to do ntrip
IPCONFIG STATIC 192.168.180.100 255.255.255.0 192.168.180.1Static IP address
Rover 192.168.180.100
Router 192.168.180.1
use a static ip address bynav 192.168.180.100 router 192.168.180.1
log ncom1 GPGGA ontime 10Send position to castersend back position to ntrip caster
NTRIPCONFIG NCOM1 CLIENT V1 IP:PORT MOUNT USERNAME PASSWORD ALLIP:PORT MOUNT USERNAME PASSWORD
needs to be adjusted
change IP:PORT MOUNT USERNAME PASSWORD
INTERFACEMODE NCOM1 RTCM BYNAVInterface settingsset interface mode
Send nmea via UDP to AgOpenGPSsend nmea via udp to agio on port 9999
ICOMCONFIG ICOM1 UDP 192.168.180.255:9999192.168.180.xxx is the IP range
Use 255 at the end to send it to everyone.
192.168.180.xxx is your ip range – use 255
INTERFACEMODE ICOM1 RTCM BYNAVInterface settingsset interface mode
log icom1 KSXT ONTIME 0.1KSXT and AgOpen send data for position, tilt, and direction.use ksxt message for position, heading and roll for agopengps
Received RTCM from AgOpenGps via UDPreceive rtcm data from agio on port 2233 – ntrip done by agopengps
ICOMCONFIG ICOM2 UDP :2233Receiving RTCM via UDP port 2233receive RTCM on UDP port 2233
INTERFACEMODE ICOM2 RTCM AUTOInterface settingsset interface mode
Use COM2 for other outputsuse com2 for another nmea output
SERIALCONFIG COM2 19200Set the baud rate of the interfaceset baud rate to your receiver
INTERFACEMODE COM2 RTCM AUTOInterface settingset interface mode
LOG COM2 GPGGA ONTIME 1Send GPGGA at 1 Hertzsend gga 1 hertz